Cummins

Cummins 11Kva Diesel Generator
Model Cummins - APS C11

cummins 50kVA genset

Salient Features
Power:
bullet Prime Power @ 50Hz : 8kw/ 10kVA
bullet Stand By Power @ 50Hz : 50Hz : 8.8kw/ 11kVA
Features:
bullet D Engine (Cummins X1.3G2)
bullet Charge alternator 12V Governor: Mechanical
bullet Alternator (Stamford PI044E)
bullet Single bearing alternator IP 23, insulation class H/H
bullet Radiator 50 C (122 F) max
bullet Skid and vibration isolators
bullet Dry type air filter
bullet Main line circuit breaker
bullet 12V battery, rack and cable
bullet Industrial silencer
bullet User manual
 
Engine Options:

Engine & Radiator:
bullet Heat shield protection
bullet Oil drain extension
bullet Heavy duty oil filter
bullet Lube oil drain pump
bullet Radiator core guard
bullet Battery charger
bullet Block header
Fuel:
bullet 24 hour day tank
bullet Bulk fuel tank connections
bullet Water separator fuel filter
Alternator:
bullet Anti-Condensation Heater
bullet Enforced impregnation
bullet Oversized alternator
Exhaust:
bullet Residential silencer
bullet Flexible exhaust connection
Enclosure:
bullet EM-1,5
bullet 83dba @ 1m silent canopy
Control Panel:
bullet Paralleling System
bullet Co-Map
bullet Remote annunciator
bullet Key start panel
Literature:
bullet Parts
bullet Maintenance
 
Engine Data
MANUFACTURER/MODEL Cummins X1.3G2 COMPRESSION RATIO 18.5:1
CYLINDER ARRANGEMENT 2 inline RATED RPM 1500Rpm
DISPLACEMENT 1.29L GOVERNOR : TYPE Mechanical
BORE AND STROKE 95 x 91mm GBMEP 2124 KPA
Alternator Data
MANUFACTURER / TYPE Stamford PI044E EXCITER TYPE NO
NUMBER OF PHASE 3 INSULATION: CLASS, TEMPERATURE RISE HH
POWER FACTOR COS PHI 0.8 VOLTAGE REGULATOR + / - 0.5%
ALTITUDE 1000 BEARING NUMBER < 2% (AT NO LOAD)
OVER SPEED RPM COUPLING BRUSHLESS
POLE: NUMBER 4 EFFICIENCIES @ 4/4 LOAD FULL
Other Alternator Data
CONTINUOUS NOMINAL RATING @ 40 C 10kVA DIRECT AXIS TRANSIENT REACTANCE ATURATED (X'd) 18.5%
STANDBY RATING @ 27 C 11kVA SHORT CIRCUIT TRANSIENT TIME CONSTANT (T'd) 18ms
EFFICIENCIES @ 4/4 LOAD 83.5% DIRECT AXIS SUBTRANSIENT REACTANCE SATURATED (X'd) 13.3%
AIR FLOW 3.5 m3/S (7416.05cfm) SUBTRANSIENT TIME CONSTANT (T'd) 12ms
SHORT CIRCUIT RATIO: 50 (Kcc) 0.78 QUADRA AXIS SUBTRANSIENT REACTANCE SATURATED (X'q) 72.7%
DIRECT AXIS SYNCHRO REACTANCE UNSATURATED (Xd) 206% ZERO SEQUENCE REACTACE UNSATURATED (Xo) 6.4%
QUADRA AXIS SYNCHRO REACTANCE UNSATURATED (Xq) 68% NEGATIVE SEQUENCE REACTANCE SATURATED (X2) 18.3%
OPEN CIRCUIT TIME CONSTANT: 50 (T'do) 0.78ms ARMATURE TIME CONSTANT (Ta) 13ms
Exhaust System
EXHAUST GAS FLOW 14.02L EXHAUST TEMPERATURE 650 C
Fuel System
100% (OF THE PRIME POWER) 3.0 L/H 75% (OF THE PRIME POWER) 2.4 L/H
50% (OF THE PRIME POWER) 1.80 L/H    
Oil System
Total oil capacity w/filters 0.79 Litres
Air Intake
MAX. INTAKE RESTRICTION COMBUSTION AIR FLOW: 108 m/min ENGINE AIR FLOW COOLING AIR FLOW: 13.38 m/min
Coolant System
RADIATOR & ENGINE CAPACITY MAX WATER TEMPERATURE CONTACT APS TEAM SALES TEAM FOR FURTHER INFORMATION
Generator Ratings
VOLTAGE HZ PHASE P.F. STANDBY AMPS STAND BY RATINGS KW/KVA PRIME RATINGS KW/KVA
415/240 50 3 1 16.5 8.8kW / 11kVA 8kW / 10kVA
220/110 50 3 1 16.5 8.8kW / 11kVA 8kW / 10kVA
RRP: Prime Power is available for an unlimited number of annual operating hours in variable load applications, in accordance with ISO 8528-1. A 10% overload capability is available for a period of 1 hour within 12hour period of operation, in accordance with ISO 3046-1.
ESP: The standby power rating is applicable for supplying emergency power in variable load applications i accordance with ISO 8528-1. Overload is not allowed
website policy | sales terms & conditions | sitemap
Home | Generators | Perkins Range of Generators | Cummins Range of Generators | Fuel Storage Tanks | Cube tanks | Containerised fuel tanks | Self Bunded Fuel tanks | Lighting towers
Copyright 2015 Assosiated Power Solutions. All rights reserved.