Ratings 380-415V, 50 Hz, 3 Phase, 1500 RPM 0.8 PF
Generator Model  Engine Model  Marelli Alternator  Cylinder & Configeration Prime Rating Standby Rating
kVA  kW  kVA  kW 
APS P13 403D-15G  MJB160SA 3 -Inline 12.5 10 13.5 10.8
APS P20  404D-22G  MJB160SB4 4 -Inline 20 16 22 17.6
APS P25 404D-22TG  MJB160MA4 4 -Inline 25 20 27.5 22
APS P30 1103A-33G1  MJB160SB4 3 - Inline 30 24 33 26.4
APS P45 1103A-33TG1  MJB200SB4 3 - Inline 45 36 50 40
APS P60   1103A-33TG2  MJB200MA4 3 - Inline 60 48 65 52
APS P80  1104A-44TG2  MJB225SA4 4-Inline 80 64 88 70.4
APS P90 1006-TG1A MJB225SB4 6 -Inline 90 72 100 80
APS P100  1104C-44TAG2  MJB225MA4 4 -Inline 100 80 110 88
APS P135 1006TAG  MJB225LA4 6 -Inline 135 108 150 120
APS P150  1006TAG2  MJB250MA4 6 -Inline 150 120 165 132
APS P180 1106C-E66TAG4  MJB250MB4 6 -Inline 180 144 200 160
APS P200  1106A-70TAG4  MJB250LA 6 -Inline 200 160 220 176
APS 230 1306C-E87TAG4 MJB250LB 6 -Inline 230 184 253 202
APS P250 1306C-E87TAG6  MJB250LB 6 -Inline 250 200 275 220
APS P350 2206A-E13TAG2  MJB315SB 6 -Inline 350 280 400 320
APS P400 2206C-E13TAG3  MJB315MA 6 -Inline 400 320 450 360
APS P450 2506A-E15TAG1  MJB315MB 6 -Inline 450 360 500 400
APS P500 2506A-E15TAG2  MJB355SA 6 -Inline 500 400 550 440
APS P600 2806A-E18TAG1A  MJB355SB 6 -Inline 600 480 660 528
APS P650 2806A-E18TAG2  MJB355MA 6 -Inline 635 508 700 560
APS P730 4006-23TAG2A  MJB355MB4 6 -Inline 730 580 800 640
APS P800 4006-23TAG3A  MJB355MB4 6 -Inline 800 640 900 720
APS P910 4008TAG1A  MJB400MA4 8 -Inline 910 728 1000 800
APS P1000 4008TAG2A MJB400MB4 8- Inline 1000 800 1100 880
APS P1250 4012-46TWG2A  MJB400LB4 12 - V 1250 1000 1375 1100
APS P1350 4012-46TAG1A MJB450MB4 12 - V 1350 1080 1500 1200
APS P1500 4012-46TAG2A  MJB450MB4 12 - V 1500 1200 1650 1320
APS 1750 4016TAG MJB450LA 16 - V 1750 1400 1925 1540
APS 2000 4016TAG1A  MJB500MB4 16 - V 2000 1600 2200 1760

Rating Definitions:

Prime:
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and these models can supply 10% overload power for 1 hour in 12 hours.


Standby:
These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility failure. No overload is permitted on these ratings. The alternators on the models are peak continuous rated (as defined in ISO 8528-3).
website policy | sales terms & conditions | sitemap
Home | Generators | Perkins Range of Generators | Cummins Range of Generators | Fuel Storage Tanks | Cube tanks | Containerised fuel tanks | Self Bunded Fuel tanks | Lighting towers
Copyright 2015 Assosiated Power Solutions. All rights reserved.